Milan Technology Network Card NDM FTX XX 01 User Manual

USER’S GUIDE  
NDM-FTX-xxxxx-01  
NDM-FTX-xxxxx-01 (standard)  
NDM-FTX-xxxxx-01(L) (low profile)  
Fast Ethernet Fiber/Dual Media NICs  
Fast Ethernet  
Copper and Fiber  
10/100Base-TX and/or 100Base-FX  
Transition Networks NDM-FTX series  
fast Ethernet dual media NIC (Network  
Interface Card) provides a 10/100Base-  
TX copper port and a 100Base-FX fiber  
port for installation flexibility in a  
mixed-media environment. The dual  
ports can also provide redundancy for  
critical applications. These NICs come in standard and low profile form factors, and  
include driver support for a variety of operating systems.  
Part Number  
Port One - Copper Port Two - Duplex Fiber-Optic  
10/100Base-TX  
100Base-FX  
RJ-45  
100 m (328 ft)*  
ST, 1300 nm multimode  
2 km (1.2 miles)*  
NDM-FTX-ST-01  
NDM-FTX-ST-01(L)  
RJ-45  
100 m (328 ft)*  
SC, 1300 nm multimode  
2 km (1.2 miles)*  
NDM-FTX-SC-01  
NDM-FTX-SC-01(L)  
RJ-45  
100 m (328 ft)*  
MT-RJ, 1300 nm multimode  
2 km (1.2 miles)*  
NDM-FTX-MT-01  
NDM-FTX-MT-01(L)  
RJ-45  
100 m (328 ft)*  
SC, 1310 nm single mode  
5 km (3.1miles)*  
NDM-FTX-SC5-01  
NDM-FTX-SC5-01(L)  
RJ-45  
100 m (328 ft)*  
SC, 1310 nm single mode  
20 km (12.4 miles)*  
NDM-FTX-SC20-01  
NDM-FTX-SC20-01(L)  
RJ-45  
100 m (328 ft)*  
SC, 1310 TX/1550nm RX single  
mode, single fiber 20 km (12.4 miles)*  
NDM-FTX-SB201-01  
NDM-FTX-SB201-01(L)  
RJ-45  
100 m (328 ft)*  
SC, 1550 TX/1310 nm RX single  
mode, single fiber 20 km (12.4 miles)*  
NDM-FTX-SB202-01  
NDM-FTX-SB202-01(L)  
Optional accessories sold separately  
Part Number  
BTR-NDM-RPL  
BTR-NDM-PXE  
Description  
RPL, Bootable ROM Chip  
PXE, Bootable ROM Chip  
*Typical maximum cable distance.  
Actual distance is dependent upon the  
physical characteristics of the network  
installation.  
Installation . . . . . . . . . . . . . . . . . . .2  
Cable Specifications . . . . . . . . . . .4  
Technical Specifications . . . . . . . .5  
Troubleshooting . . . . . . . . . . . . . . .6  
Contact Us . . . . . . . . . . . . . . . . . . .7  
 
NDM-FTX Series Fast Ethernet Dual Media NIC  
Fiber cable -- continued  
Cable Specifications  
Copper cable  
NDM-FTX-SB202-01(x)  
1550 TX/1310 RX nm single mode  
single stand  
10BASE-T UTP Category 3, 4, 5 or higher  
100Base-TX UTP Category 5 or higher  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
min: -14.0 dBm  
min: -32.0 dBm  
18.0 dB  
max: -8.0 dBm  
max: 0.0 dBm  
Gauge:  
24 to 22AWG  
Attenuation:  
22.0 dB /100m @ 100 MHz  
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-  
825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.  
Straight-through MDI twisted-pair cable must be used.  
Shielded STP or unshielded UTP twisted-pair cable may be used.  
Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.  
RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-  
Use only dedicated wire pairs for the active pins:  
Technical Specifications  
For models NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-01(L)  
(e.g., blue/white and white/blue, orange/white and white/orange, etc.)  
DO NOT use flat or silver satin wire.  
Standards:  
Expansion bus standard:  
Data rate:  
IEEE 802.3  
PCI 2.1, 2.2  
10/100Mpbs twisted pair media  
100Mbps fiber media  
LINK/ACT (on the bracket)  
ON = communication link; flashing = activity on link  
FDX (full duplex link); ON = full duplex link  
• NetWare Server 4.1x, 5.x  
• Netware DOS Client ODI  
• Windows 95, 98, 2000, 2003, XP, NT4.0  
• Linux  
Novell RPL Boot ROM; PXE Boot ROM  
2.5” W x 5.9” D x 0.85” H  
(63.5 mm W x 149.9 mm D x 21.6 mm H)  
3 oz. (91g) approximate  
1.0A @ +5VDC  
198,853 hours (Bellcore7 V5.0)  
0°C to 50°C (32°F to 122°F)  
-25°C to 85°C (-13°F to 185°F)  
5% to 90%, non-condensing  
0 to 10,000 feet  
Straight-Through Cable  
1
2
1
2
Twisted Pair #1  
Twisted Pair #2  
LED:  
3
6
3
6
Drivers:  
The physical characteristics must meet or exceed the IEEE 802.3 specification.  
Fiber cable  
Bit error rate:  
<10-9  
Boot server support:  
PCB dimensions:  
Single mode fiber (recommended):  
Multimode fiber (recommended):  
Multimode fiber (optional):  
9 µm  
62.5/125 µm  
100/140, 85/140, 50/125 µm  
Weight:  
Power consumption:  
MTBF  
Operating temp  
Storage temp:  
Humidity:  
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x) 1300 nm multimode  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
min: -19.0 dBm  
min: -31.0 dBm  
12.0 dB  
max: -14.0 dBm  
max: -17.0 dBm  
NDM-FTX-SC5-01(x)  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
1310 nm single mode  
max: -14.0 dBm  
max: -7.5 dBm  
min: -19.0 dBm  
min: -31.0 dBm  
12.0 dB  
Altitude:  
Warranty:  
Lifetime  
NDM-FTX-SC20-01(x)  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
1310 nm single mode  
max: -8.0 dBm  
min: -15.0 dBm  
min: -31.0 dBm  
16.0 dB  
WARNING: Visible and invisible laser radiation when open: DO NOT stare into  
the beam or view directly with optical instruments. Failure to observe this warning  
could result in damage to your vision or blindness.  
max: 0.0 dBm  
NDM-FTX-SB201-01(x)  
1310 TX/1550 RX nm single mode  
single stand  
CAUTION: Use of controls, adjustments, or the performance of procedures other  
than those specified herein may result in hazardous radiation exposure.  
Fiber optic transmitter power:  
Fiber optic receiver sensitivity:  
Link budget:  
min: -14.0 dBm  
min: -32.0 dBm  
18.0 dB  
max: -8.0 dBm  
max: 0.0 dBm  
The information in this manual is subject to change without further notice.  
5
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours  
[email protected] -- Click the “Transition Now” link for live Web chat.  
 
NDM-FTX Series Fast Ethernet Dual Media NIC  
Troubleshooting  
Diagnostics LEDs and Boot ROM  
Contact Us  
Technical support  
Technical support is available at [email protected]  
LEDS  
• US and Canada:  
• International:  
1-800-260-1312 (24 hours)  
The LINK/ACT LED lights when a fiber cable or twisted pair cable connection  
is good. It blinks to indicate activity.  
00-1-952-941-7600 (24 hours)  
Transition now  
The collision and full-duplex LED report board operating status.  
Chat live via the Web with Transition Networks Technical Support. Log onto  
Boot ROM  
Web-based seminar  
Transition networks provides seminars via live, web-based training. Log onto  
To add the remote boot feature to a workstation, insert the Boot ROM into the  
ROM socket. See Figure 1 on page 2.  
After power UP, the LINK/ACT LED should light; if not, check the following:  
Email  
1
Confirm that the NDM-FTX module is properly inserted into the PC  
workstation master slot or file-server master slot.  
Ask a question anytime by sending an email to our technical support staff:  
2
Confirm that the PC workstation or the file server is properly connected to  
a power source and with the power source turned ON.  
Address  
Transition Networks  
3
4
Check the fiber cable and twisted-pair copper cables for proper connection.  
6475 City West Parkway  
Minneapolis, MN 55344, U.S.A.  
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600 if those  
steps fail to produce the desired result.  
Telephone:  
Toll free:  
Fax:  
952-941-7600,  
800-526-9267  
952-941-2322  
Note: To connect this device to a router, bridge, or switch, please refer to the  
corresponding technical manual for the device.  
Declaration of Conformity  
Name of Mfg:  
Model:  
Transition Networks, 6475 City West Parkway,  
Minneapolis, MN 55344 U.S.A.  
NDM-FTX-xxxxx-0l and NDM-FTX-xxxxx-0l(L) Network Interface  
Cards  
Part Number:  
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x),  
NDM-FTX-SC5-01(x), NDM-FTX-SC20-01(x),  
NDM-FTX-SB201-01(x), NDM-FTX-SB202-01(x)  
Regulation:  
Purpose:  
EMC Directive 89/336/EEC  
To declare that the NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-0l(L), to  
which this declaration refers, is in conformity with the following  
standards:  
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B; 21CFR  
subpart J  
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and  
Standard(s).  
June 30, 2005  
Stephen Anderson, Vice-President of Engineering  
Date  
7
6
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours  
[email protected] -- Click the “Transition Now” link for live Web chat.  
 
Compliance Information  
CISPR22/EN55022 Class A, CE Mark, CISPR22/EN55022 Class A + EN55024, CE Mark  
FCC regulations  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at the user's own expense.  
Canadian regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  
on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage  
radioélectrique édicté par le ministère des Communications du Canada.  
European regulations  
Caution: This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei  
Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für  
Gegenmaßnahmen verantwortlich.  
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de  
créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures  
spécifiques appropriées.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
Trademark notice  
All registered trademarks and trademarks are the property of their respective owners.  
Copyright restrictions  
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or  
used in any form or by any means—graphic, electronic or mechanical—without written permission  
from Transition Networks  
Printed in the US  
Manual Part Number and Rev.  
33332.A  
 

MSi Computer Hardware 865GM3 User Manual
Napoleon Fireplaces Indoor Fireplace GD80NT User Manual
NordicTrack Treadmill NTTL18991 User Manual
Nortel Networks Network Card AA1419005 User Manual
One for All Universal Remote URC 6690 User Manual
Panasonic Cordless Telephone KX PRS120 User Manual
Panasonic Network Card 2SD0814A User Manual
Panasonic Switch AJ8R User Manual
Panasonic Telephone KX FPG378 User Manual
Paradyne Network Card 8310 MVLt User Manual