Instruction Manual 637IT Fully automatic blood pressure monitor for measurement at the wrist
Gebrauchsanweisung 637IT Vollautomatisches Blutdruckmeßgerät zur Messung am Handgelenk
Gebruiksaanwijzing 637IT Volledig automatische bloeddrukmeter voor de pols
Manuel d'instructions 637IT Tensiomètre entièrement automatique pour prise de mesure au poignet
Manual de instrucciones 637IT Aparato completamente automático para medir la presión arterial en la muñeca
Manuale di instruzioni 637IT Misuratore della pressione per il polso completamente automatico
English • Deutsch • Nederlands • Français • Italiano • Español
637IT Vers.01/07/02
1
Notes on Safety
Main unit
Batteries for monitoring
Storage case
(Two LR03 alkaline batteries)
Important instructions for obtaining meaningful readings
Avoid eating and drinking (alcohol), smoking, sport and taking medicines before measuring your
blood pressure as this could affect your blood pressure level.
Before you start sit comfortably on a chair and relax. It is recommended to check your blood pressure
at least twice a day, in the morning after getting up and in the evening after work, or as advised by
your doctor.
Do not move and do not speak while the measurement is being taken. Avoid measuring your blood
pressure while you are in a moving vehicle.
Allow an interval of at least three minutes between readings. Otherwise congestion of blood might
occur and distort the readings. Always remove the cuff between readings.
USB computer interface cable
CD-ROM
Instruction Manual
Bare your wrist and take of your watch and jewellery before applying the cuff. Do not constrict the
flow of your blood if you push up your sleeve.
Cautions
Blood pressure measurement is not suitable in case of serious arteriosclerosis (hardening of the
arteries).
The pulse rate indicator is not suitable for monitoring the frequency of cardiac pacemakers.
If you suffer from disorders of heart rhythm, known as arrythmia, you should only use this blood pres-
sure monitor in consultation with your doctor. In certain cases oscillometric measurement methods
can produce incorrect readings.
Names and Functions of the Parts
Pregnant women should only measure their own blood pressure in consultation with their doctor since
the readings may be changed by the pregnancy.
Please remember: Self-measurement is not the same as medical treatment! You should never
change the dose of medicines as prescribed by your doctor!
Data Transfer Port
Connects your 637IT
with your PC.
Before using your OMRON 637IT for the first time
Main unit
Your blood pressure monitor: the benefits
The OMRON 637IT is a compact fully automatic wrist blood pressure monitor. Operating on the oscil-
lometric principle it measures your blood pressure and pulse rate comfortable and quickly from the
wrist. It contains an intelligent system for “fuzzy” controlled inflation, known as “Intellisense”. This is
an advanced method of oscillometric measurement. No pre-setting of re-inflation is necessary.
The OMRON 637IT has a Position Sensor. The Position Sensor is able to determine the optimal
height of your wrist (heart level) for the blood pressure measurement. Measuring at the heart level is
extremely important since measuring at a higher or lower position will give wrong results.
Wrist Cuff
The OMRON 637IT has a large DOT matrix display enabling you to enlarge the digits and showing
you graphs. Together with the USB computer interface and the built in alarm function for same time
measurements or pill intake your OMRON 637IT is the optimal device to manage your blood pres-
sure.
Battery Cover
4
5
Please disconnect your 637IT from your PC when you replace the batteries.
Systolic Blood
Pressure Display
With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal
conditions. Please switch of the monitor after using it. If you forget to switch the monitor off it will
switch off itself after app. 2 minutes. Please take the batteries out of the monitor if you intend not to
use the monitor for a long period (app. 2 months).
MEMORY
RECALL button
Push this button to
see the measured
values stored in
the monitor.
Diastolic Blood
Pressure Display
How to Set the Date and Time
Date/Time Display
GRAPH CALL
button
Before using your OMRON 637IT for the first time, you have to
set the date and time. After turning the monitor on by pushing the
O/I button the initial screen (see picture) will be available for a
few seconds. After the initial screen you will proceed automatical-
ly to the TIME SET screen. (For instruction how to set the date
and time refer also to page 16 in Chapter How to change the set-
Mark
Displayed when a stored
measurement is shown.
Push this button to
see the graph.
ON/OFF button
Push this button to
measure your
tings.)
Pulse Display
Initial Screen
blood pressure or
to switch the moni-
tor off.
After reaching the time screen you will see the Gregorian calen-
dar (year day/month). The year will be flashing.
button
Push to move the displayed item
forward. Push to move the dis-
played item backward.
SETTING button
1. By using the (
) buttons you can set the current year.
Push this button to set
various items on the moni-
tor such as time and date.
2. By pushing the SET button you will lock the year and proceed
to the next item.
For setting the month, date and time repeat step 1 and 2. After
setting the minutes you will proceed to the DELETE DATA
screen. Please turn off your monitor by pushing the O/I button.
Your OMRON 637IT is ready for use now.
Time Screen
How to Insert the Batteries
Use this monitor after inserting batteries in the main unit.
1.
2.
Open the battery compartment.
How to Measure Blood Pressure Correctly
How to wrap the cuff
In order to measure your blood pressure correctly it is needed to wrap the cuff around your wrist in a
correct way. If not, correct measurements are not possible. Please follow the coming instructions (left
wrist):
Insert the batteries (Type LR03 / AAA) as shown in the figure.
Ensure the polarity (+/-) of the batteries is correct.
1) Make sure that your wrist is bare and will be wrapped over your skin.
2) Make sure that you clothing is not constraining the flow of your blood.
3) Make sure that the wrist (left or right) to measure is selected from the settings menu (see also
page 15). The left wrist is preset.
3.
Close the battery cover.
6
7
How to obtain a correct posture
10~15mm
Achieving a correct posture before measuring your blood pressure is important since an incorrect
posture might give you incorrect readings. To achieve a correct posture please follow the instructions
(see pictures):
4) Place the cuff over your left wrist with your thumb facing upwards.
Leave app 10-15 mm between the cuff and the bottom of the palm of your
hand as shown in the figures.
1) Sit down and stretch your back.
2) Relax yourself by relieving the stress from your shoulders and arms.
3) Breath several times deeply and return to natural respiration.
4) Do not sustain your wrist with your other hand and avoid stress in your hand by making firm grips
or large extensions.
Correct Posture
4) Pull the wrist cuff upward and close the cuff firmly with the Velcro tape
as shown.
1
2
3
Incorrect Posture
Measuring your blood pressure and pulse
If you have achieved the correct posture you can start the measurement. When you measure for the
first time the Position Sensor and the Signal will be ON and measuring at the left wrist will be pre set.
• Push the O/I button to activate your
637IT and the Position Sensor
Screen will be displayed.
You can use your 637IT also on your right hand after selecting right wrist
measurement in the SETTING MODE.
People with a slender wrist (wrist circumference of less than 145mm) may
feel loose because the cuff may not be wrapped firmly. Please do not force
the cuff it will not affect the measurement.
8
9
How to enlarge the reading
How to Measure Blood Pressure
• The results will be shown on your display. By pushing the (
) buttons you can enlarge the
readings.
• Sustain your elbow with your other hand
or a table to avoid movement.
• Adjust the height of your wrist by using your elbow as a fulcrum. When the (
) will reach the
(
) signyou will hear a beeping sound indicating that your blood pressure monitor is at the correct
height (heart height). The (
) sign will change in the (
) sign and the measurement will start.
How to Use the Memory Function
Your OMRON 637IT blood pressure monitor is able to store maxi-
mum 90 measurements including date and time. When your blood
pressure monitor is holding 90 measurements the oldest will be
deleted to store a new measurement.
Inflation Start Screen
Mark
Indicating
Inflation in
Progress
• Do not move until the measurement results are
displayed!
• The screens (see picture) will be shown during the
measurement.
Pulse
Rate
Mark
Press the (M) memory button when your blood pressure monitor is
switched off. The latest measurement will be displayed. Each time
you push (
) button an earlier measurement will be displayed. By
pushing the ( ) button a later reading is displayed.
Inflation in Progress
Screen
By pushing the GRAPH button the selected measurement is dis-
played in a weekly graph (see also How to use the graph function).
Push the memory button to return to the memory display again.
When the measurement is finishes, the deflation mark
(
) flashed and the cuff deflates.
Deflation
Mark
Date and
Time of
Deflation Start Screen
Measurement
Measurement Results
Display Screen
10
11
Explanation of the graph display
Blood Pressure Values (sys-
tolic/diastolic) (mmHg)
How to use the graph function
This monitor has the possibility to display the stored measurements as a graph. In order to get a clear
history of your blood pressure the measurements are put in time zones:
• Morning: Measurements made between 0:00 and 9:59
• Daytime: Measurements made between 10:00 and 17:59
• Evening: Measurements made between 18:00 and 23:59
The last measurement in each time zone will be displayed. For example if you measure 3 times in the
same time zone on the same day only the third reading will be displayed. On the other hand all read-
ings will be stored in the memory (See also page 11).
Date of
Measurement
When the GRAPH button is pushed the latest
measurement will appear in a flashing display.
In the example the measurement is made on
January 31 at 22:40. The graph shows 140
mmHg for systolic and 95 mmHg for diastolic
(top and bottom of vertical bar) and a pulse rate
of 90 beats a minute.
There are three different graphs available:
• All data graph: displays all measurements per week
• Morning data graph: displays all morning measurements per week
• Evening data graph: displays all evening measurements per week
No graph display is provided for daytime data only.
Pulse
Rate
Month/Days of a Week
When you push the memory button in the
graph display the details of the measurement
will appear. Pushing the graph button again will
bring you back the graph display. You can use
To display the graph push the GRAPH CALL button.
(
) the arrows in the graph and memory dis-
play to leaf through the measurements.
Detail Screen of Data
in Flashing Display
All Data Graph is displayed.
The systolic blood pressure is higher than
170mmHg
When a systolic blood pressure above 170
All Data Graph
mmHg is measured twice the (
displayed in the graph.
) symbol is
When a systolic blood pressure above 170
mmHg is measured three times the (
bol disappears and the screen automatically
changes to the “hypertension display”. The
maximum displayed blood pressure value
(y-axis) will change from 170 mmHg to 210
mmHg.
) sym-
Push the GRAPH CALL button again to display the
Morning Data Graph.
Morning
Display screen where the Graph Display Screen of
systolic blood pressure
values higher than 170
mmHg are measured
twice
Hypertension Type
Data
Mark
Morning Data Graph
How to change the settings
Push the GRAPH CALL button again to display the
Evening Data Graph.
Night
The settings of your OMRON 637IT blood pressure monitor can be changed according to your own
preferences and comfort.
Data
Mark
• Each time you push the GRAPH CALL button, All,
Morning, and Evening data are displayed in that
order repeatedly.
To enter the setting menu please press the SET button when your blood pressure monitor is switched
off. By using (
) you can select your preference. By pressing the SET button again you lock your
preference and proceed to the next item as shown in the figure. The on/off button (O/I) can be used to
switch the monitor off again.
Night Data Graph
12
13
Position sensor
The position sensor of your OMRON 637IT can be switched ON or OFF. In
the factory preset the position sensor is enabled. If the position sensor is
switched ON you can choose to have the optimal wrist height supported by
an acoustic sound (SIGNAL ON or OFF).
• If you push the SETTING button while the power is turned off,
the Setting Screen is displayed in the order shown in the picture.
• You can select the setting or set the date and time with the
buttons.
• To finish the setting, push the ON/OFF button.
Position Sensor Screen
Position Sensor ON and
SIGNAL OFF Screen
Position Sensor Setting
(Refer to Page 15.)
Measuring (Wrist) Setting
(Refer to Page 15.)
Automatic Memory Setting
(Refer to Page 14.)
Position Sensor OFF
Screen
Left or right wrist measurement
Normally blood pressure is measured on the left wrist (factory preset). With your OMRON 637IT you
can choose to use the monitor either on your left or right wrist. It is recommended to use the same
wrist when for optimal comparisons of your blood pressure fluctuations.
Alarm Setting
(Refer to Page 15.)
Time Setting
(Refer to Page 16.)
All Memory Erasure
(Refer to Page 16.)
Reset Settings
(Refer to Page 16.)
Measuring (Wrist) Screen
Measuring (Wrist) Right Wrist Screen
Alarm
Your blood pressure monitor has the possibility to set an alarm twice a day. The alarm function can
be used to monitor your blood pressure at the same time every day or as a reminder for pill intake.
The alarm will sound for 2 minutes. By pushing the O/I button the alarm will stop. The alarm will not
sound when the blood pressure monitor is used (e.g. for measuring or graph display) at the moment
the alarm is set.
Auto memory
You can set the requested hour by pushing (
ceed with the minutes. By pushing the (
) when flashing. Press SET to lock the hour and pro-
) you can set the minutes. Press SET to confirm and to
You can either enable (ON) or disable (OFF) the memory function of your
blood pressure. When the auto memory function is switched off the measure-
ment will not be stored. When using your OMRON 637IT monitor with more
than one person it is recommended to disable the auto memory function. The
auto memory function mode is ON when you purchased your OMRON 637IT
(factory preset).
proceed. Push either (
) to enable (
) or disable (
) the alarm. Press SET to lock the settings.
Automatic Memory
Screen
Screen of indicating that
the alarm is sounding
Alarm Screen
Automatic Memory
OFF Screen
14
15
Time
How to use the computer interface
You can change the time and date setting of your blood pressure monitor.
When reaching the time screen you will see the Gregorian calendar. The
year will be flashing.
This blood pressure monitor has a computer interface and is supplied with software to transfer the
memory of the blood pressure monitor to your personal computer.
1. By using the (
2. By pushing the SET button you will lock the year and proceed
to the next setting.
) buttons you can set the current year.
Required operating environment
The following operating environment is required to operate the communication software as supplied
Time Screen
on the CD-ROM.
Personal computer
:
PC/AT compatible with CPU of 80486 or above or with
any Pentium processor.
For setting the month, date and time repeat step 1 and 2. After setting
the minutes you will proceed to the DELETE DATA screen.
OS
:
:
:
:
:
:
Windows 98SE/ME/XP/2000
16 MB or more
Memory (RAM)
Hard disk
Display
Free area of 10 MB or more is necessary
640 x 480 pixels or more
Delete data
All Memory Erasure
YES Screen
Disk drive
Connection port
CD-ROM drive
In this screen you are able to delete all stored measurement from you
OMRON 637IT. Please be careful that deleted data cannot be restored.
The factory preset is NO. If you choose YES the monitor will ask for a
confirmation “ARE YOU SURE?”. To cancel select NO to confirm
DELETE DATA select YES.
Free USB connection port
How to install the software
1) Turn on your personal computer
......Your windows desktop is displayed
2) Insert the CD-ROM in the disk drive
3) Open the control panel
After deleting all stored measurements the “Data Deleted Screen” will be
shown. All the stored measurements are deleted and the monitor will be
turned off.
Are You Sure YES
Screen
• Click the “Start” button.
• Point the mouse pointer to “Settings” on the menu.
• Click “Control Panel”
If the stored measurements are not deleted you will proceed to the
RESET SETTINGS screen.
4) Open the “Add/Remove Programs” by double clicking the icon
5) Execute the installation
• Click the “install button”
• Follow the instructions
Data Deleted (Blank)
Screen
• The software is installed on your personal computer
Reset settings
How to uninstall the software
In this menu you can choose to reset all the settings to the “factory pre-
set” settings. The factory preset for this menu is NO. If you choose YES
1) Open the control panel
• Click the “Start” button
by using the (
) button the monitor will ask you for a confirmation “ARE
• Choose “Settings”
YOU SURE?” After confirmation by selecting YES all the settings will be
changed to the factory mode.
• Click “Control Panel”
Reset Settings YES
Screen
2) Open the “Add/Remove Prograns” icon by double clicking
3) Delete the application
The monitor will return to the AUTO MEMORY SCREEN. You can turn off
your monitor by pushing the O/I button.
• Click “BPFile” from the list
• Click the Add/Remove button
• .....The confirmation screen is displayed
• Click “Yes”
• .....”BPFile” is deleted
• Click “OK”
Are You Sure YES Screen
16
17
How to connect your 637IT blood pressure monitor to your PC
How to create a data file
• Press the “DATA” button on your screen
• Press the “Dir” button on your screen and
name the file.
Connect your 637IT blood pressure monitor with your PC using the included USB cable. The mini
USB connector (small connector) should be connected to your 637IT blood pressure monitor and the
normal USB connector (large connector) should be plugged into your personal computer.
• Press “OK”
• The file can be opened in most windows
programs like Excel, Word
How to use the software
Open the BPFile application from the program list or your desktop and the following screen is shown
on the screen.
How to set the time
• Press the “TIME” button on your screen.
...The time and date are read from your 637IT blood pressure monitor
• Change the time and date if applicable in the white field
•
•
•
•
By pressing the “DATA” button your are able to transfer the memory of your 637IT blood
pressure monitor to your personal computer.
By pressing the “TIME” button you are able to set the date and time in your 637IT blood
pressure monitor.
By pressing the “ID” button you are able to set your personal name in your 637IT blood
pressure monitor.
By pressing the “CLOSE” button you are closing the program.
18
19
Hypertension guide
What is blood pressure?
Systolic blood pressure
Diastolic blood pressure
Systolic blood pressure
(mmHg)
The World Health Organization (WHO) and the
International Society of Hypertension (ISH) estab-
lished the Blood Pressure Classification. Use this
Classification as the guide to know the state of your
blood pressure. However, if you are concerned with
your blood pressure, be sure to follow the instructions
of your doctor.
Blood is pumped to artery by the beat (con-
traction and expansion) of a pump called the
heart. The pressure to pump out blood to
artery is called the "systolic blood pressure."
The pressure when the heart expands as the
blood having circulated the whole body
returns is called the "diastolic blood pres-
sure."
Blood is pumped out.
Blood returns to heart.
Severe hypertension
Vascular
wall
Vascular
Vein
180
160
Artery
Moderate hypertension
wall
Mild hypertension
140
130
120
Pressure
to vascular
wall
Pressure to
Normal systolic value
Contraction
Expansion
vascular wall
drops.
Normal blood pressure
increases.
Optimal blood
pressure
Diastolic
blood
• There is no universally accepted definition of
hypotension. Generally speaking, those with the
systolic pressure below 100 mmHg are considered
to be hypotension.
pressure
(mmHg)
(target value)
90
100
110
80
85
Health and blood pressure
According to the blood pressure classification by the WHO/ISH* (revised in 1999)
* International Society of Hypertension
Lifestyle
Excessive intake of salt,
Excessive consumption of alcohol,
Obesity, Lack of exercise
Blood pressure fluctuates being affected by
everyday life and age. Hypertension is a sign
that can cause dangerous diseases such as
cerebral apoplexy or myocardial infarction to
occur easily. By understanding the state of
your blood pressure, review your health and
lifestyle.
• This classification is made based on the
blood pressure values measured at upper
arm by sitting on the chair in the hospital
regardless of the age.
Hypertension
Arterial sclerosis
Danger of Cerebral apoplexy, Myocardial infarction
Blood pressure at the upper arm and wrist
Wrist Blood Pressure Monitor
Blood pressure is usually measured at brachial artery.
As the wrist arterial vessel is connected to the brachial ves-
sel, wrist blood pressure values are close to brachial ones
and reflect the change of brachial blood pressures.
However in case there is a circulatory disorder such as
arterial infarction, fairly large difference is observed
between the brachial and the wrist blood pressure values.
After consulting with your doctor, use the wrist blood pres-
sure together with the brachial pressure for your health
management.
Brachial
artery
Wrist artery
(Radial artery)
(Ulnar artery)
Heart
20
21
Diseases influencing blood pressure values
Diabetes, hyperlipemia, or hypertension accelerates arterial
Error indication
sclerosis, which causes dangerous disease such as cerebral
apoplexy or myocardial infarction or induces arterial stenosis
or peripheral circulatory disorder.
If the measurement is not made correctly, the following error can be displayed.
In these cases, the wrist and brachial blood pressure values
may differ greatly. (Even in healthy people, a difference of 20
mmHg may occur if the measuring conditions are not proper.
Therefore do not try to diagnose the measurement values by
yourself, but be sure to follow the instructions of your doctor.)
In addition, difference of wrist and brachial blood pressure val-
ues may somewhat get affected by the physiological condi-
tions at the time of measurement. However, the blood pres-
sure values measured at wrist and upper arm usually fluctuate
in the same manner.
Error
Cause
How to correct
Measure your blood pres-
sure again without moving
your wrist until the meas-
urement is completed.
(Refer to Page 10.)
You moved your wrist
during measurement.
After several seconds
Measure your blood pres-
sure again without moving
your arm or body.
You moved your arm or
body, or talked during
measurement.
Therefore, you can check the fluctuation tendency of blood
pressure by measuring the wrist blood pressure.
(Refer to Page 10.)
After several seconds
Differences between blood pressure measured at home and at the doctor’s office
Normally blood pressure measured at home tends to be lower than when measured at the doctor’s
office. This can be as much as 20 mmHg due to that you feel more relaxed at home and feel slightly
tense when visiting the doctor. To manage your blood pressure it is important to monitor and register
your blood pressure at home.
Measure your blood pres-
sure again without moving
your arm or body.
You moved your arm or
body extensively during
measurement.
Since blood pressure is fluctuating from beat to beat and is influenced by daily activities measure-
ments can differ from measurement to measurement.
(Refer to Page 10.)
After several seconds
Maintenance and storage
Replace both batteries with
new ones.
• For cleaning the monitor only use a soft, lightly moistened cloth.
• Do not use petroleum spirits, thinners or similar solvents!
Batteries are worn out.
(Refer to Page 6.)
• Stains on the cuff can be carefully removed using a moist cloth and soapy water.
Battery replacement mark flashes.
• Do not wash the cuff or make it wet. Please make sure no water will enter the main unit!
• Keep your monitor in the storage case protected from extreme temperatures and humidity.
• Do not carry out repairs of any kind yourself. If a defect occurs consult your OMRON dealer or dis-
tributor.
Trouble caused by abnor-
mality in function.
Please contact the nearest
OMRON dealer.
• Please take the batteries out if the monitor is not used for a long period (app. 2 months or more).
Only E and numerals are displayed.
• Electro Magnetic fields can influence the measurement. Do not use a protable phone near the unit.
Disposal of this product and used batteries should be carried out in
accordance with the national regulations for the disposal of electronic
products.
• If you cannot resolve the problem even after taking the above-mentioned measures, please con-
tact the nearest OMRON dealer.
22
23
Troubleshooting
Spare parts and accessories
OMRON considers, due to the used high company and quality standards, the main unit as a
non-serviceable part because of the necessity of proper calibration after replacement of high-tech
components.
Trouble
Possible cause
How to correct
Replace the batteries with new ones.
(See to Page 6.)
Batteries are worn out.
The cuff can be replaced by an authorised expert.
Nothing is displayed when
you push the ON/OFF
button.
Specifications
The directions of polarities
of inserted batteries
Insert the batteries correctly.
(Refer to Page 6.)
Name :
OMRON Fully Automatic Blood Pressure Monitor
for measurement on the wrist
(+ and -) are wrong.
Model :
637IT
Measure your blood pressure again in
correct posture.
The wrist cuff is not held
at the level of the heart.
Display :
Dot matrix LCD display
(Refer to Page 9.)
Measurement :
Measurement Range :
Accuracy :
Oscillometric method
Pressure; 0 to 299 mmHg, Pulse rate; 40 to 180 /min.
Pressure; within +/-3 mmHg, Pulse rate; within +/-5% of reading
Automatic inflation with pump
Measurement cannot be
made.
The wrist cuff is not
wrapped firmly.
Wrap the wrist cuff correctly. (Refer to
Page 7.)
Or the blood pressure
values are displayed abnor-
mally high (low).
Inflation :
Too much stress is applied
on your shoulder or arm.
Relax yourself and make measure-
ment.
Deflation :
Automatic rapid deflation
Pressure Detection :
Power supply :
Battery Life :
Electrostatic capacity semi-conductor pressure sensor
Two LR03 batteries (AAA)
You are talking or moving
your hands during meas-
urement.
Be still and make measurement.
Approximately 300 times of measurement when using alkaline
batteries (In case of the monitor is used three times a day inflat-
ing to 170 mmHg at the room temperature of 22°C)
The blood pressure values
differ from the values meas-
ured at brachial.
Refer to the section on "Wrist Blood Pressure Monitor."
(Refer to Page 21.)
Operating Temperature
and Humidity :
+10° to +40°C, 30 to 85% RH
Storage temperature
and humidity :
Blood pressure values are
displayed before the monitor
inflates to the required
value.
Contact the store where the
-20° to +60°C, 10 to 95% RH
Air is leaking from the wrist cuff.
unit was sold or the nearest
OMRON distributor.
Measurable
circumference of wrist :
135 to 215 mm
Weight of Main Unit :
External Dimensions :
Electric Shock Protection :
Accessories :
Approximately 150 g (not including batteries)
78 (W) x 65.5 (H) x 37.2 (D) mm (not including the wrist cuff)
Internal power supply appliance type B
Blood pressure value fluc-
tuates each time of mea-
surement.
Or the blood pressure val-
ues are displayed abnormal-
ly high (low).
Blood pressure value tends to fluctuate depending on the mental
state during measurement or the measuring time. Breathe deeply to
relax yourself and make measurement again.
(Refer to Page 22.)
Two LR03 alkaline batteries for monitoring use, storage case,
Instruction Manual, USB cable, software
• In the interest of product improvement, specifications are subject to change without notice.
• If you cannot resolve the problem even after taking the above-mentioned measures, please contact
EU-Representative:
OMRON Healthcare Europe B.V.
Kruisweg 577
the nearest OMRON dealer or distributor.
=Type B
NL-2132-NA Hoofddorp
24
25
|