Omron Blood Pressure Monitor 637IT User Manual

Instruction Manual 637IT Fully automatic blood pressure monitor for measurement at the wrist  
Gebrauchsanweisung 637IT Vollautomatisches Blutdruckmeßgerät zur Messung am Handgelenk  
Gebruiksaanwijzing 637IT Volledig automatische bloeddrukmeter voor de pols  
Manuel d'instructions 637IT Tensiomètre entièrement automatique pour prise de mesure au poignet  
Manual de instrucciones 637IT Aparato completamente automático para medir la presión arterial en la muñeca  
Manuale di instruzioni 637IT Misuratore della pressione per il polso completamente automatico  
English • Deutsch • Nederlands • Français • Italiano • Español  
637IT Vers.01/07/02  
 
1
Notes on Safety  
Main unit  
Batteries for monitoring  
Storage case  
(Two LR03 alkaline batteries)  
Important instructions for obtaining meaningful readings  
Avoid eating and drinking (alcohol), smoking, sport and taking medicines before measuring your  
blood pressure as this could affect your blood pressure level.  
Before you start sit comfortably on a chair and relax. It is recommended to check your blood pressure  
at least twice a day, in the morning after getting up and in the evening after work, or as advised by  
your doctor.  
Do not move and do not speak while the measurement is being taken. Avoid measuring your blood  
pressure while you are in a moving vehicle.  
Allow an interval of at least three minutes between readings. Otherwise congestion of blood might  
occur and distort the readings. Always remove the cuff between readings.  
USB computer interface cable  
CD-ROM  
Instruction Manual  
Bare your wrist and take of your watch and jewellery before applying the cuff. Do not constrict the  
flow of your blood if you push up your sleeve.  
Cautions  
Blood pressure measurement is not suitable in case of serious arteriosclerosis (hardening of the  
arteries).  
The pulse rate indicator is not suitable for monitoring the frequency of cardiac pacemakers.  
If you suffer from disorders of heart rhythm, known as arrythmia, you should only use this blood pres-  
sure monitor in consultation with your doctor. In certain cases oscillometric measurement methods  
can produce incorrect readings.  
Names and Functions of the Parts  
Pregnant women should only measure their own blood pressure in consultation with their doctor since  
the readings may be changed by the pregnancy.  
Please remember: Self-measurement is not the same as medical treatment! You should never  
change the dose of medicines as prescribed by your doctor!  
Data Transfer Port  
Connects your 637IT  
with your PC.  
Before using your OMRON 637IT for the first time  
Main unit  
Your blood pressure monitor: the benefits  
The OMRON 637IT is a compact fully automatic wrist blood pressure monitor. Operating on the oscil-  
lometric principle it measures your blood pressure and pulse rate comfortable and quickly from the  
wrist. It contains an intelligent system for fuzzycontrolled inflation, known as Intellisense. This is  
an advanced method of oscillometric measurement. No pre-setting of re-inflation is necessary.  
The OMRON 637IT has a Position Sensor. The Position Sensor is able to determine the optimal  
height of your wrist (heart level) for the blood pressure measurement. Measuring at the heart level is  
extremely important since measuring at a higher or lower position will give wrong results.  
Wrist Cuff  
The OMRON 637IT has a large DOT matrix display enabling you to enlarge the digits and showing  
you graphs. Together with the USB computer interface and the built in alarm function for same time  
measurements or pill intake your OMRON 637IT is the optimal device to manage your blood pres-  
sure.  
Battery Cover  
 
4
5
Please disconnect your 637IT from your PC when you replace the batteries.  
Systolic Blood  
Pressure Display  
With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal  
conditions. Please switch of the monitor after using it. If you forget to switch the monitor off it will  
switch off itself after app. 2 minutes. Please take the batteries out of the monitor if you intend not to  
use the monitor for a long period (app. 2 months).  
MEMORY  
RECALL button  
Push this button to  
see the measured  
values stored in  
the monitor.  
Diastolic Blood  
Pressure Display  
How to Set the Date and Time  
Date/Time Display  
GRAPH CALL  
button  
Before using your OMRON 637IT for the first time, you have to  
set the date and time. After turning the monitor on by pushing the  
O/I button the initial screen (see picture) will be available for a  
few seconds. After the initial screen you will proceed automatical-  
ly to the TIME SET screen. (For instruction how to set the date  
and time refer also to page 16 in Chapter How to change the set-  
Mark  
Displayed when a stored  
measurement is shown.  
Push this button to  
see the graph.  
ON/OFF button  
Push this button to  
measure your  
tings.)  
Pulse Display  
Initial Screen  
blood pressure or  
to switch the moni-  
tor off.  
After reaching the time screen you will see the Gregorian calen-  
dar (year day/month). The year will be flashing.  
button  
Push to move the displayed item  
forward. Push to move the dis-  
played item backward.  
SETTING button  
1. By using the (  
) buttons you can set the current year.  
Push this button to set  
various items on the moni-  
tor such as time and date.  
2. By pushing the SET button you will lock the year and proceed  
to the next item.  
For setting the month, date and time repeat step 1 and 2. After  
setting the minutes you will proceed to the DELETE DATA  
screen. Please turn off your monitor by pushing the O/I button.  
Your OMRON 637IT is ready for use now.  
Time Screen  
How to Insert the Batteries  
Use this monitor after inserting batteries in the main unit.  
1.  
2.  
Open the battery compartment.  
How to Measure Blood Pressure Correctly  
How to wrap the cuff  
In order to measure your blood pressure correctly it is needed to wrap the cuff around your wrist in a  
correct way. If not, correct measurements are not possible. Please follow the coming instructions (left  
wrist):  
Insert the batteries (Type LR03 / AAA) as shown in the figure.  
Ensure the polarity (+/-) of the batteries is correct.  
1) Make sure that your wrist is bare and will be wrapped over your skin.  
2) Make sure that you clothing is not constraining the flow of your blood.  
3) Make sure that the wrist (left or right) to measure is selected from the settings menu (see also  
page 15). The left wrist is preset.  
3.  
Close the battery cover.  
 
6
7
How to obtain a correct posture  
10~15mm  
Achieving a correct posture before measuring your blood pressure is important since an incorrect  
posture might give you incorrect readings. To achieve a correct posture please follow the instructions  
(see pictures):  
4) Place the cuff over your left wrist with your thumb facing upwards.  
Leave app 10-15 mm between the cuff and the bottom of the palm of your  
hand as shown in the figures.  
1) Sit down and stretch your back.  
2) Relax yourself by relieving the stress from your shoulders and arms.  
3) Breath several times deeply and return to natural respiration.  
4) Do not sustain your wrist with your other hand and avoid stress in your hand by making firm grips  
or large extensions.  
Correct Posture  
4) Pull the wrist cuff upward and close the cuff firmly with the Velcro tape  
as shown.  
1
2
3
Incorrect Posture  
Measuring your blood pressure and pulse  
If you have achieved the correct posture you can start the measurement. When you measure for the  
first time the Position Sensor and the Signal will be ON and measuring at the left wrist will be pre set.  
Push the O/I button to activate your  
637IT and the Position Sensor  
Screen will be displayed.  
You can use your 637IT also on your right hand after selecting right wrist  
measurement in the SETTING MODE.  
People with a slender wrist (wrist circumference of less than 145mm) may  
feel loose because the cuff may not be wrapped firmly. Please do not force  
the cuff it will not affect the measurement.  
 
8
9
How to enlarge the reading  
How to Measure Blood Pressure  
The results will be shown on your display. By pushing the (  
) buttons you can enlarge the  
readings.  
Sustain your elbow with your other hand  
or a table to avoid movement.  
Adjust the height of your wrist by using your elbow as a fulcrum. When the (  
) will reach the  
(
) signyou will hear a beeping sound indicating that your blood pressure monitor is at the correct  
height (heart height). The (  
) sign will change in the (  
) sign and the measurement will start.  
How to Use the Memory Function  
Your OMRON 637IT blood pressure monitor is able to store maxi-  
mum 90 measurements including date and time. When your blood  
pressure monitor is holding 90 measurements the oldest will be  
deleted to store a new measurement.  
Inflation Start Screen  
Mark  
Indicating  
Inflation in  
Progress  
• Do not move until the measurement results are  
displayed!  
The screens (see picture) will be shown during the  
measurement.  
Pulse  
Rate  
Mark  
Press the (M) memory button when your blood pressure monitor is  
switched off. The latest measurement will be displayed. Each time  
you push (  
) button an earlier measurement will be displayed. By  
pushing the ( ) button a later reading is displayed.  
Inflation in Progress  
Screen  
By pushing the GRAPH button the selected measurement is dis-  
played in a weekly graph (see also How to use the graph function).  
Push the memory button to return to the memory display again.  
When the measurement is finishes, the deflation mark  
(
) flashed and the cuff deflates.  
Deflation  
Mark  
Date and  
Time of  
Deflation Start Screen  
Measurement  
Measurement Results  
Display Screen  
 
10  
11  
Explanation of the graph display  
Blood Pressure Values (sys-  
tolic/diastolic) (mmHg)  
How to use the graph function  
This monitor has the possibility to display the stored measurements as a graph. In order to get a clear  
history of your blood pressure the measurements are put in time zones:  
Morning: Measurements made between 0:00 and 9:59  
Daytime: Measurements made between 10:00 and 17:59  
Evening: Measurements made between 18:00 and 23:59  
The last measurement in each time zone will be displayed. For example if you measure 3 times in the  
same time zone on the same day only the third reading will be displayed. On the other hand all read-  
ings will be stored in the memory (See also page 11).  
Date of  
Measurement  
When the GRAPH button is pushed the latest  
measurement will appear in a flashing display.  
In the example the measurement is made on  
January 31 at 22:40. The graph shows 140  
mmHg for systolic and 95 mmHg for diastolic  
(top and bottom of vertical bar) and a pulse rate  
of 90 beats a minute.  
There are three different graphs available:  
All data graph: displays all measurements per week  
Morning data graph: displays all morning measurements per week  
Evening data graph: displays all evening measurements per week  
No graph display is provided for daytime data only.  
Pulse  
Rate  
Month/Days of a Week  
When you push the memory button in the  
graph display the details of the measurement  
will appear. Pushing the graph button again will  
bring you back the graph display. You can use  
To display the graph push the GRAPH CALL button.  
(
) the arrows in the graph and memory dis-  
play to leaf through the measurements.  
Detail Screen of Data  
in Flashing Display  
All Data Graph is displayed.  
The systolic blood pressure is higher than  
170mmHg  
When a systolic blood pressure above 170  
All Data Graph  
mmHg is measured twice the (  
displayed in the graph.  
) symbol is  
When a systolic blood pressure above 170  
mmHg is measured three times the (  
bol disappears and the screen automatically  
changes to the hypertension display. The  
maximum displayed blood pressure value  
(y-axis) will change from 170 mmHg to 210  
mmHg.  
) sym-  
Push the GRAPH CALL button again to display the  
Morning Data Graph.  
Morning  
Display screen where the Graph Display Screen of  
systolic blood pressure  
values higher than 170  
mmHg are measured  
twice  
Hypertension Type  
Data  
Mark  
Morning Data Graph  
How to change the settings  
Push the GRAPH CALL button again to display the  
Evening Data Graph.  
Night  
The settings of your OMRON 637IT blood pressure monitor can be changed according to your own  
preferences and comfort.  
Data  
Mark  
Each time you push the GRAPH CALL button, All,  
Morning, and Evening data are displayed in that  
order repeatedly.  
To enter the setting menu please press the SET button when your blood pressure monitor is switched  
off. By using (  
) you can select your preference. By pressing the SET button again you lock your  
preference and proceed to the next item as shown in the figure. The on/off button (O/I) can be used to  
switch the monitor off again.  
Night Data Graph  
 
12  
13  
Position sensor  
The position sensor of your OMRON 637IT can be switched ON or OFF. In  
the factory preset the position sensor is enabled. If the position sensor is  
switched ON you can choose to have the optimal wrist height supported by  
an acoustic sound (SIGNAL ON or OFF).  
If you push the SETTING button while the power is turned off,  
the Setting Screen is displayed in the order shown in the picture.  
You can select the setting or set the date and time with the  
buttons.  
To finish the setting, push the ON/OFF button.  
Position Sensor Screen  
Position Sensor ON and  
SIGNAL OFF Screen  
Position Sensor Setting  
(Refer to Page 15.)  
Measuring (Wrist) Setting  
(Refer to Page 15.)  
Automatic Memory Setting  
(Refer to Page 14.)  
Position Sensor OFF  
Screen  
Left or right wrist measurement  
Normally blood pressure is measured on the left wrist (factory preset). With your OMRON 637IT you  
can choose to use the monitor either on your left or right wrist. It is recommended to use the same  
wrist when for optimal comparisons of your blood pressure fluctuations.  
Alarm Setting  
(Refer to Page 15.)  
Time Setting  
(Refer to Page 16.)  
All Memory Erasure  
(Refer to Page 16.)  
Reset Settings  
(Refer to Page 16.)  
Measuring (Wrist) Screen  
Measuring (Wrist) Right Wrist Screen  
Alarm  
Your blood pressure monitor has the possibility to set an alarm twice a day. The alarm function can  
be used to monitor your blood pressure at the same time every day or as a reminder for pill intake.  
The alarm will sound for 2 minutes. By pushing the O/I button the alarm will stop. The alarm will not  
sound when the blood pressure monitor is used (e.g. for measuring or graph display) at the moment  
the alarm is set.  
Auto memory  
You can set the requested hour by pushing (  
ceed with the minutes. By pushing the (  
) when flashing. Press SET to lock the hour and pro-  
) you can set the minutes. Press SET to confirm and to  
You can either enable (ON) or disable (OFF) the memory function of your  
blood pressure. When the auto memory function is switched off the measure-  
ment will not be stored. When using your OMRON 637IT monitor with more  
than one person it is recommended to disable the auto memory function. The  
auto memory function mode is ON when you purchased your OMRON 637IT  
(factory preset).  
proceed. Push either (  
) to enable (  
) or disable (  
) the alarm. Press SET to lock the settings.  
Automatic Memory  
Screen  
Screen of indicating that  
the alarm is sounding  
Alarm Screen  
Automatic Memory  
OFF Screen  
 
14  
15  
Time  
How to use the computer interface  
You can change the time and date setting of your blood pressure monitor.  
When reaching the time screen you will see the Gregorian calendar. The  
year will be flashing.  
This blood pressure monitor has a computer interface and is supplied with software to transfer the  
memory of the blood pressure monitor to your personal computer.  
1. By using the (  
2. By pushing the SET button you will lock the year and proceed  
to the next setting.  
) buttons you can set the current year.  
Required operating environment  
The following operating environment is required to operate the communication software as supplied  
Time Screen  
on the CD-ROM.  
Personal computer  
:
PC/AT compatible with CPU of 80486 or above or with  
any Pentium processor.  
For setting the month, date and time repeat step 1 and 2. After setting  
the minutes you will proceed to the DELETE DATA screen.  
OS  
:
:
:
:
:
:
Windows 98SE/ME/XP/2000  
16 MB or more  
Memory (RAM)  
Hard disk  
Display  
Free area of 10 MB or more is necessary  
640 x 480 pixels or more  
Delete data  
All Memory Erasure  
YES Screen  
Disk drive  
Connection port  
CD-ROM drive  
In this screen you are able to delete all stored measurement from you  
OMRON 637IT. Please be careful that deleted data cannot be restored.  
The factory preset is NO. If you choose YES the monitor will ask for a  
confirmation ARE YOU SURE?. To cancel select NO to confirm  
DELETE DATA select YES.  
Free USB connection port  
How to install the software  
1) Turn on your personal computer  
......Your windows desktop is displayed  
2) Insert the CD-ROM in the disk drive  
3) Open the control panel  
After deleting all stored measurements the Data Deleted Screenwill be  
shown. All the stored measurements are deleted and the monitor will be  
turned off.  
Are You Sure YES  
Screen  
Click the Startbutton.  
Point the mouse pointer to Settingson the menu.  
Click Control Panel”  
If the stored measurements are not deleted you will proceed to the  
RESET SETTINGS screen.  
4) Open the Add/Remove Programsby double clicking the icon  
5) Execute the installation  
Click the install button”  
Follow the instructions  
Data Deleted (Blank)  
Screen  
The software is installed on your personal computer  
Reset settings  
How to uninstall the software  
In this menu you can choose to reset all the settings to the factory pre-  
setsettings. The factory preset for this menu is NO. If you choose YES  
1) Open the control panel  
Click the Startbutton  
by using the (  
) button the monitor will ask you for a confirmation ARE  
Choose Settings”  
YOU SURE?After confirmation by selecting YES all the settings will be  
changed to the factory mode.  
Click Control Panel”  
Reset Settings YES  
Screen  
2) Open the Add/Remove Progransicon by double clicking  
3) Delete the application  
The monitor will return to the AUTO MEMORY SCREEN. You can turn off  
your monitor by pushing the O/I button.  
Click BPFilefrom the list  
Click the Add/Remove button  
.....The confirmation screen is displayed  
Click Yes”  
.....BPFileis deleted  
Click OK”  
Are You Sure YES Screen  
 
16  
17  
How to connect your 637IT blood pressure monitor to your PC  
How to create a data file  
Press the DATAbutton on your screen  
Press the Dirbutton on your screen and  
name the file.  
Connect your 637IT blood pressure monitor with your PC using the included USB cable. The mini  
USB connector (small connector) should be connected to your 637IT blood pressure monitor and the  
normal USB connector (large connector) should be plugged into your personal computer.  
Press OK”  
The file can be opened in most windows  
programs like Excel, Word  
How to use the software  
Open the BPFile application from the program list or your desktop and the following screen is shown  
on the screen.  
How to set the time  
Press the TIMEbutton on your screen.  
...The time and date are read from your 637IT blood pressure monitor  
Change the time and date if applicable in the white field  
By pressing the DATAbutton your are able to transfer the memory of your 637IT blood  
pressure monitor to your personal computer.  
By pressing the TIMEbutton you are able to set the date and time in your 637IT blood  
pressure monitor.  
By pressing the IDbutton you are able to set your personal name in your 637IT blood  
pressure monitor.  
By pressing the CLOSEbutton you are closing the program.  
 
18  
19  
Hypertension guide  
What is blood pressure?  
Systolic blood pressure  
Diastolic blood pressure  
Systolic blood pressure  
(mmHg)  
The World Health Organization (WHO) and the  
International Society of Hypertension (ISH) estab-  
lished the Blood Pressure Classification. Use this  
Classification as the guide to know the state of your  
blood pressure. However, if you are concerned with  
your blood pressure, be sure to follow the instructions  
of your doctor.  
Blood is pumped to artery by the beat (con-  
traction and expansion) of a pump called the  
heart. The pressure to pump out blood to  
artery is called the "systolic blood pressure."  
The pressure when the heart expands as the  
blood having circulated the whole body  
returns is called the "diastolic blood pres-  
sure."  
Blood is pumped out.  
Blood returns to heart.  
Severe hypertension  
Vascular  
wall  
Vascular  
Vein  
180  
160  
Artery  
Moderate hypertension  
wall  
Mild hypertension  
140  
130  
120  
Pressure  
to vascular  
wall  
Pressure to  
Normal systolic value  
Contraction  
Expansion  
vascular wall  
drops.  
Normal blood pressure  
increases.  
Optimal blood  
pressure  
Diastolic  
blood  
There is no universally accepted definition of  
hypotension. Generally speaking, those with the  
systolic pressure below 100 mmHg are considered  
to be hypotension.  
pressure  
(mmHg)  
(target value)  
90  
100  
110  
80  
85  
Health and blood pressure  
According to the blood pressure classification by the WHO/ISH* (revised in 1999)  
* International Society of Hypertension  
Lifestyle  
Excessive intake of salt,  
Excessive consumption of alcohol,  
Obesity, Lack of exercise  
Blood pressure fluctuates being affected by  
everyday life and age. Hypertension is a sign  
that can cause dangerous diseases such as  
cerebral apoplexy or myocardial infarction to  
occur easily. By understanding the state of  
your blood pressure, review your health and  
lifestyle.  
This classification is made based on the  
blood pressure values measured at upper  
arm by sitting on the chair in the hospital  
regardless of the age.  
Hypertension  
Arterial sclerosis  
Danger of Cerebral apoplexy, Myocardial infarction  
Blood pressure at the upper arm and wrist  
Wrist Blood Pressure Monitor  
Blood pressure is usually measured at brachial artery.  
As the wrist arterial vessel is connected to the brachial ves-  
sel, wrist blood pressure values are close to brachial ones  
and reflect the change of brachial blood pressures.  
However in case there is a circulatory disorder such as  
arterial infarction, fairly large difference is observed  
between the brachial and the wrist blood pressure values.  
After consulting with your doctor, use the wrist blood pres-  
sure together with the brachial pressure for your health  
management.  
Brachial  
artery  
Wrist artery  
(Radial artery)  
(Ulnar artery)  
Heart  
 
20  
21  
Diseases influencing blood pressure values  
Diabetes, hyperlipemia, or hypertension accelerates arterial  
Error indication  
sclerosis, which causes dangerous disease such as cerebral  
apoplexy or myocardial infarction or induces arterial stenosis  
or peripheral circulatory disorder.  
If the measurement is not made correctly, the following error can be displayed.  
In these cases, the wrist and brachial blood pressure values  
may differ greatly. (Even in healthy people, a difference of 20  
mmHg may occur if the measuring conditions are not proper.  
Therefore do not try to diagnose the measurement values by  
yourself, but be sure to follow the instructions of your doctor.)  
In addition, difference of wrist and brachial blood pressure val-  
ues may somewhat get affected by the physiological condi-  
tions at the time of measurement. However, the blood pres-  
sure values measured at wrist and upper arm usually fluctuate  
in the same manner.  
Error  
Cause  
How to correct  
Measure your blood pres-  
sure again without moving  
your wrist until the meas-  
urement is completed.  
(Refer to Page 10.)  
You moved your wrist  
during measurement.  
After several seconds  
Measure your blood pres-  
sure again without moving  
your arm or body.  
You moved your arm or  
body, or talked during  
measurement.  
Therefore, you can check the fluctuation tendency of blood  
pressure by measuring the wrist blood pressure.  
(Refer to Page 10.)  
After several seconds  
Differences between blood pressure measured at home and at the doctors office  
Normally blood pressure measured at home tends to be lower than when measured at the doctors  
office. This can be as much as 20 mmHg due to that you feel more relaxed at home and feel slightly  
tense when visiting the doctor. To manage your blood pressure it is important to monitor and register  
your blood pressure at home.  
Measure your blood pres-  
sure again without moving  
your arm or body.  
You moved your arm or  
body extensively during  
measurement.  
Since blood pressure is fluctuating from beat to beat and is influenced by daily activities measure-  
ments can differ from measurement to measurement.  
(Refer to Page 10.)  
After several seconds  
Maintenance and storage  
Replace both batteries with  
new ones.  
For cleaning the monitor only use a soft, lightly moistened cloth.  
Do not use petroleum spirits, thinners or similar solvents!  
Batteries are worn out.  
(Refer to Page 6.)  
Stains on the cuff can be carefully removed using a moist cloth and soapy water.  
Battery replacement mark flashes.  
Do not wash the cuff or make it wet. Please make sure no water will enter the main unit!  
Keep your monitor in the storage case protected from extreme temperatures and humidity.  
Do not carry out repairs of any kind yourself. If a defect occurs consult your OMRON dealer or dis-  
tributor.  
Trouble caused by abnor-  
mality in function.  
Please contact the nearest  
OMRON dealer.  
Please take the batteries out if the monitor is not used for a long period (app. 2 months or more).  
Only E and numerals are displayed.  
Electro Magnetic fields can influence the measurement. Do not use a protable phone near the unit.  
Disposal of this product and used batteries should be carried out in  
accordance with the national regulations for the disposal of electronic  
products.  
If you cannot resolve the problem even after taking the above-mentioned measures, please con-  
tact the nearest OMRON dealer.  
 
22  
23  
Troubleshooting  
Spare parts and accessories  
OMRON considers, due to the used high company and quality standards, the main unit as a  
non-serviceable part because of the necessity of proper calibration after replacement of high-tech  
components.  
Trouble  
Possible cause  
How to correct  
Replace the batteries with new ones.  
(See to Page 6.)  
Batteries are worn out.  
The cuff can be replaced by an authorised expert.  
Nothing is displayed when  
you push the ON/OFF  
button.  
Specifications  
The directions of polarities  
of inserted batteries  
Insert the batteries correctly.  
(Refer to Page 6.)  
Name :  
OMRON Fully Automatic Blood Pressure Monitor  
for measurement on the wrist  
(+ and -) are wrong.  
Model :  
637IT  
Measure your blood pressure again in  
correct posture.  
The wrist cuff is not held  
at the level of the heart.  
Display :  
Dot matrix LCD display  
(Refer to Page 9.)  
Measurement :  
Measurement Range :  
Accuracy :  
Oscillometric method  
Pressure; 0 to 299 mmHg, Pulse rate; 40 to 180 /min.  
Pressure; within +/-3 mmHg, Pulse rate; within +/-5% of reading  
Automatic inflation with pump  
Measurement cannot be  
made.  
The wrist cuff is not  
wrapped firmly.  
Wrap the wrist cuff correctly. (Refer to  
Page 7.)  
Or the blood pressure  
values are displayed abnor-  
mally high (low).  
Inflation :  
Too much stress is applied  
on your shoulder or arm.  
Relax yourself and make measure-  
ment.  
Deflation :  
Automatic rapid deflation  
Pressure Detection :  
Power supply :  
Battery Life :  
Electrostatic capacity semi-conductor pressure sensor  
Two LR03 batteries (AAA)  
You are talking or moving  
your hands during meas-  
urement.  
Be still and make measurement.  
Approximately 300 times of measurement when using alkaline  
batteries (In case of the monitor is used three times a day inflat-  
ing to 170 mmHg at the room temperature of 22°C)  
The blood pressure values  
differ from the values meas-  
ured at brachial.  
Refer to the section on "Wrist Blood Pressure Monitor."  
(Refer to Page 21.)  
Operating Temperature  
and Humidity :  
+10° to +40°C, 30 to 85% RH  
Storage temperature  
and humidity :  
Blood pressure values are  
displayed before the monitor  
inflates to the required  
value.  
Contact the store where the  
-20° to +60°C, 10 to 95% RH  
Air is leaking from the wrist cuff.  
unit was sold or the nearest  
OMRON distributor.  
Measurable  
circumference of wrist :  
135 to 215 mm  
Weight of Main Unit :  
External Dimensions :  
Electric Shock Protection :  
Accessories :  
Approximately 150 g (not including batteries)  
78 (W) x 65.5 (H) x 37.2 (D) mm (not including the wrist cuff)  
Internal power supply appliance type B  
Blood pressure value fluc-  
tuates each time of mea-  
surement.  
Or the blood pressure val-  
ues are displayed abnormal-  
ly high (low).  
Blood pressure value tends to fluctuate depending on the mental  
state during measurement or the measuring time. Breathe deeply to  
relax yourself and make measurement again.  
(Refer to Page 22.)  
Two LR03 alkaline batteries for monitoring use, storage case,  
Instruction Manual, USB cable, software  
In the interest of product improvement, specifications are subject to change without notice.  
If you cannot resolve the problem even after taking the above-mentioned measures, please contact  
EU-Representative:  
OMRON Healthcare Europe B.V.  
Kruisweg 577  
the nearest OMRON dealer or distributor.  
=Type B  
NL-2132-NA Hoofddorp  
 
24  
25  

Milnor Sprinkler KWACSD001R User Manual
Milwaukee Cordless Drill 2605 20 User Manual
NAD Universal Remote HTR 3 User Manual
Nokia Cable Box CA 55 User Manual
Nokia Headphones HS 6 User Manual
NordicTrack Home Gym NTL19921 User Manual
OPTI UPS Network Card AV Mate Junior User Manual
Panasonic Car Stereo System CQ 5251JU User Manual
Panasonic Garage Door Opener CZ RTC2 User Manual
Panasonic Laptop Docking Station CF VEB342 User Manual