Panasonic AW PB506AL User Manual

Studio SDI Card  
AW-PB506AL  
This product consists of an SDI card and an  
interface bracket.  
Before attempting to connect, operate or adjust this product,  
please read these instructions completely.  
Information on Disposal for Users of Waste Electrical & Electronic  
Equipment (private households)  
This symbol on the products and/or accompanying documents  
means that used electrical and electronic products should not be  
mixed with general household waste.  
For proper treatment, recovery and recycling, please take these  
products to designated collection points, where they will be accepted  
on a free of charge basis. Alternatively, in some countries you may  
be able to return your products to your local retailer upon the purchase of an  
equivalent new product.  
Disposing of this product correctly will help to save valuable resources and prevent  
any potential negative effects on human health and the environment which could  
otherwise arise from inappropriate waste handling.  
Please contact your local authority for further details of your nearest designated  
collection point.  
Penalties may be applicable for incorrect disposal of this waste, in accordance with  
national legislation.  
For business users in the European Union  
If you wish to discard electrical and electronic equipment, please contact your  
dealer or supplier for further information.  
Information on Disposal in other Countries outside the European  
Union  
This symbol is only valid in the European Union.  
If you wish to discard this product, please contact your local authorities or dealer  
and ask for the correct method of disposal.  
- ꢀ (E) -  
Contents  
Configuration ........................................ 3  
Accessories .......................................... 3  
Introduction ........................................... 4  
Characteristics ...................................... 4  
Precautions for use .............................. 4  
Connections .......................................... 9  
When configuring a system  
with the remote control unit ......... 9  
When configuring a system  
with the remote operation panel ... 10  
Setting and changing of menu items ... 11  
Performing the settings .................. 11  
Optional card settings submenu .... 1ꢀ  
Major operating controls and  
their functions ................................. 5  
SDI card ........................................... 5  
Interface bracket .............................. 6  
Appearance ......................................... 14  
SDI card ......................................... 14  
Interface bracket ............................ 15  
Installing the SDI card .......................... 7  
Specifications ..................................... 16  
Interface bracket mountings ............... 8  
Mounting the bracket on a tripod ..... 8  
Mounting the camera ....................... 8  
Mounting the viewfinder  
on a bracket.................................. 8  
Configuration  
SDI card (AW-PB506A U01) ................... 1  
Interface bracket (AW-PB506A U02) .... 1  
Accessories  
Adjuster plug (M6 M3) ........................ 1  
Screws (6 mm) ....................................... 2  
Screws (8 mm) ....................................... 4  
- ꢀ (E) -  
Introduction  
Installing the SDI card in a convertible  
camera (such as the AW-Eꢀ50, AW-E650,  
AW-E655, AW-E750 and AW-E860) and  
mounting the camera on the interface  
bracket makes it possible for a viewfinder  
and/or inter-communications headset to  
be used and thus enable the camera to  
be used as a studio camera. In addition,  
there are two signal outputs for SDI signals  
Notes  
The AW-PB506A cannot be installed  
to the following models;  
AW-Eꢀ00, AW-Eꢀ00A, AW-Eꢀ00S,  
AW-E600, AW-E800, AW-E800A,  
AW-RP605, AW-PB605  
When the SDI card unit is to be  
discarded at the end of its service  
life, ask a specialized contractor  
to dispose of it properly in order to  
protect the environment.  
c
ompliant with EBU Tech.ꢀꢁ67-E standard.  
Characteristics  
Two signal outputs for SDI signals  
compliant with the EBU Tech.ꢀꢁ67-E  
standard (BBC No. PSF1/ꢁM, BELDEN  
8ꢁ81 or equivalent coaxial cable; max.  
ꢁ00 m)  
EDH (Error Detection and Handling)  
flags complying with the SMPTE RP165  
standard can be added.  
Output signals (brightness and  
composite video signals) to the  
viewfinder can be switched using the  
menu settings.  
Zebra pattern and safety zone displays  
appearing in the viewfinder can be  
switched using the menu settings.  
(A switch can be used to enable or  
disable the addition of these flags.)  
The VIDEO ON/OFF switch function of  
the viewfinder (AW-VF64) is incorporated.  
(In order to prevent CRT burn-in, the  
AW-VF64 does not come with a standby  
function.)  
An inter-communications headset can be  
used and its volume adjusted.  
The STANDBY/ON switch function of  
the viewfinder (WV-VF65B, AW-VF80) is  
incorporated.  
Precautions for use  
When connecting or disconnecting a  
cable from any unit, ensure that the  
power to that unit is turned off.  
Avoid using the unit in very humid or  
dusty locations, as this may cause it to  
malfunction.  
Do not drop this product or subject it to  
strong shock or vibration, as this may  
cause it to malfunction.  
Avoid using the product at a cold place  
below –10°C or at a hot place above  
+45°C because extremely low or high  
temperature will adversely affect the  
parts inside.  
- 4 (E) -  
Major operating controls and their functions  
SDI card  
2: Model selection <E350/E860>  
(Factory setting: Eꢁ50)  
EVF I/F connector [EVF I/F]  
The EVF I/F cable 9 from the interface  
bracket is connected here.  
When the AW-Eꢁ50, AW-E650,  
AW-E655 or AW-E750 is used, set  
this switch at the Eꢁ50.  
When the AW-E860 is used, set this  
switch at the E860.  
SDI output 1, 2 connector  
[SDI OUT 1, 2]  
SDI signals are output from here.  
3: DATA CLIP <NORMAL/CLIP>  
(Factory setting: NORMAL)  
At the NORMAL setting, signal input  
is output at the same level at which it  
was input.  
Setting switches  
At the CLIP setting, signal input at  
less than 0% is output at 0%, and  
signal input at more than 100% is  
clipped at 100%.  
SW NO  
EDH  
SETTING  
OFF  
ON  
1
ENABLE DISABLE  
Eꢁ50  
E860  
CLIP  
PAL  
4: NTSC/PAL switching <NTSC/PAL>  
(Factory setting: NTSC)  
ꢁ DATA CLIP NORMAL  
4 NTSC/PAL NTSC  
Leave this switch at the factory setting.  
1: EDH <ENABLE/DISABLE>  
(Factory setting: ENABLE)  
An EDH flag is added to SDI output at  
the ENABLE setting.  
- 5 (E) -  
Major operating controls and their functions  
Interface bracket  
EVF connector 1 [EVF1]  
The viewfinder (WV-VF65B, AW-VF80)  
is connected here.  
7
Inter-communications level control  
[LEVEL]  
This adjusts the sound level output to  
the inter-communications headset.  
5EVF connector 2 [EVF2]  
The viewfinder AW-VF64 is connected  
here.  
8Inter-communications jack (M3)  
[INCOM]  
The inter-communications headset is  
connected here.  
If the plug diameter does not match, use  
the adjuster plug (M6 Mꢁ) supplied  
with this product.  
Note  
Do not connect EVFs to EVF  
connectors 1 and ꢀ (and 5) at  
the same time.  
MIC:  
Dynamic (With Preamp)  
50 /–ꢀ0 dB  
6EVF standby / VIDEO ON/OFF  
switch  
Receiver: 150 (max. ꢀ00 mW)  
[ST.BY / VIDEO ON/OFF]  
<For the WV-VF65B, AW-VF80>  
ST.BY: Places the viewfinder in standby  
mode.  
9EVF I/F cable  
This is connected to the EVF I/F  
connector on the SDI card.  
ON:  
Outputs images to the viewfinder.  
TALLY input connector [TALLY IN]  
This is the tally control external input  
connector.  
<For the AW-VF64>  
VIDEO ON: Outputs images to the  
viewfinder.  
VIDEO OFF: No images appear on the  
viewfinder.  
OPEN: TALLY OFF  
SHORT: TALLY ON  
When using the AW-CB400 remote  
operation panel and AW-CA50T8G  
control cable for connecting to the  
convertible camera, connect the TALLY  
cable of the AW-CA50T8G to this  
connector.  
The AW-VF64 does not come with a  
standby function.  
- 6 (E) -  
Installing the SDI card  
Always ask your local dealer to install the SDI card.  
Before installing the SDI card:  
Release the static carried in the body of the person to perform the installation.  
Installation can be performed more safely if an anti-static wrist strap is worn.  
Touching the card without first releasing this static may cause malfunctioning.  
Do not allow the metal part of the card come in contact with any other metal parts.  
Rear panel  
Optional card  
slot cover  
SDI card  
2 screws (6 mm)  
4 screws (8 mm)  
1
5
6
Turn the power to the camera off  
and remove any cables which are  
connected to the power connector or  
other connectors.  
Firmly tighten the ꢀ screws (6 mm) to  
the optional card slot.  
Firmly secure the rear panel with the  
4 screws (8 mm).  
2
3
4
Loosen the 4 screws (8 mm) on the  
rear panel of the camera, then remove  
the panel itself.  
Note  
If the screws are misplaced, use  
the extra screws supplied with this  
product.  
Loosen the ꢀ screws (6 mm) on the  
optional card slot cover, then remove  
the cover.  
Align the SDI card with the guides and  
insert it.  
Ensure the card is fully inserted.  
- 7 (E) -  
Interface bracket mountings  
Mounting the bracket  
on a tripod  
Mounting the viewfinder  
on a bracket  
3
1
Mount the mounting base that is  
supplied to the viewfinder onto the top  
of the interface bracket using the ꢀ  
screws provided.  
Mount the interface bracket on the  
tripod. (Screw: 1/4 – ꢀ0UNC)  
(Mount the base securely so that it is  
not unsteady.)  
Mounting base  
2 screws  
4
5
6
Slide the viewfinder onto the mounting  
base and tighten the fixing knob to  
secure it firmly.  
Connect the viewfinder cable to the  
EVF connector 1 or ꢀ on the interface  
bracket.  
Mounting the camera  
2
Mount the camera (in which the  
SDI card has been installed) on the  
interface bracket.  
Connect the EVF I/F cable from  
the interface bracket to the EVF I/F  
connector on the SDI card.  
Fasten the fixing knob to firmly secure  
the camera.  
<WV-VF65B,  
AW-VF80, etc.>  
Fixing knob  
Fixing knob  
Fixing knob  
<AW-VF64>  
- 8 (E) -  
Connections  
When configuring a system with the remote control unit  
Convertible camera:  
AW-Eꢀ50, AW-E650, AW-E655,  
Inter-communications headset  
Video monitor  
AW-E750, AW-E860, etc.  
SDI monitor  
Viewfinder:  
WV-VF65B, AW-VF80, AW-VF64, etc.  
Use the RCU cable (AW-CA50Aꢁ6) to  
connect the remote control unit to the  
convertible camera.  
Power to the camera is supplied from the  
remote control unit.  
Remote control unit (RCU):  
WV-RC700A, WV-RC550, AW-RC600,  
etc.  
Inter-communications headset  
Viewfinder:  
WV-VF65B, AW-VF80,  
AW-VF64, etc.  
Convertible camera:  
AW-Eꢀ50, AW-E650, AW-E655,  
AW-E750, AW-E860, etc.  
SDI monitor  
SDI output  
Coaxial cable:  
BBC No. PSF1/ꢁM, BELDEN  
8ꢁ81 or equivalent coaxial  
cable max. ꢁ00 m  
Remote control unit (RCU):  
WV-RC700A, WV-RC550,  
AW-RC600, etc.  
Video monitor  
Composite signals  
Coaxial cable  
Inter-communications headset  
RCU cable:  
AW-CA50Aꢁ6  
- 9 (E) -  
Connections  
When configuring a system with the remote operation panel  
Convertible camera:  
AW-Eꢀ50, AW-E650, AW-E655,  
AW-E750, AW-E860, etc.  
Use the control cable (AW-CA50T8G) to  
connect the remote operation panel to  
the convertible camera.  
Use the AW-PS505A AC adapter, which  
is an optional accessory, for the power  
supply.  
Viewfinder:  
WV-VF65B, AW-VF80, AW-VF64, etc.  
Remote operation panel:  
AW-CB400, etc.  
Inter-communication between the  
remote operation panel and studio SDI  
card is not possible.  
Video monitor  
SDI monitor  
Viewfinder:  
WV-VF65B, AW-VF80,  
AW-VF64, etc.  
TALLY cable  
Convertible camera:  
AW-Eꢀ50, AW-E650,  
AW-E655, AW-E750,  
AW-E860, etc.  
SDI monitor  
Coaxial cable:  
SDI output  
BBC No. PSF1/ꢁM, BELDEN  
8ꢁ81 or equivalent coaxial  
cable max. ꢁ00 m  
AC adapter:  
AW-PS505A  
Cable provided  
with AC adapter  
Remote operation  
panel:  
AW-CB400, etc.  
Video monitor  
10BASE-T  
straight cable  
Cable provided with AC adapter  
AC adapter:  
AW-PS505A  
Control cable:  
AW-CA50T8G  
- 10 (E) -  
Setting and changing of menu items  
Camera settings to match the system configuration and filming conditions can be made  
using the menu screens.  
See the convertible camera operating instructions for more information on the settings.  
For details on the setting procedures when the remote control unit and remote operation  
panel are used, refer to the operating instructions of the unit and panel.  
Main menu for user mode  
Performing the settings  
1
Display the main menu.  
When performing the settings with  
the convertible camera:  
Press the MENU switch continuously  
for at least 5 seconds.  
When performing the settings with  
the remote control unit (AW-RC600):  
Set the MENU switch to “ON”.  
* “Option Card 2” is displayed on the  
menu when the optional card has been  
Main menu for halogen light mode,  
fluorescent light mode and outdoor mode  
plugged into the optional card slot of  
the additional card box.  
The mode selected is displayed here.  
Convertible camera  
MENU switch  
ITEM/AWC switch  
YES/ABC switch  
NO/BAR switch  
To return to filming mode  
(This is displayed when the convertible  
camera is used to perform the settings.)  
Remote control unit (AW-RC600)  
MENU switch  
ITEM UP switch  
ITEM DOWN switch  
DATAYES/UP switch  
DATA NO/DOWN switch  
- 11 (E) -  
Setting and changing of menu items  
2
4
Select “Option Card 1” to display the  
submenu.  
Return to filming mode.  
When performing the settings with  
the convertible camera:  
Press the MENU or ITEM/AWC  
switch and select “End” on the main  
menu, then press the YES/ABC  
switch.  
When performing the settings with  
the convertible camera:  
Press the MENU or ITEM/AWC  
switch to move the flashing to the  
setting item, then press the YES/ABC  
switch to display the submenu.  
When performing the settings with  
the remote control unit (AW-RC600):  
Set the MENU switch to “OFF”.  
When performing the settings with  
the remote control unit (AW-RC600):  
Press the ITEM UP or ITEM DOWN  
switch to move the flashing to the  
setting item, then press the DATA  
YES/UP switch to display the  
submenu.  
After being returned to filming mode,  
the convertible camera will operate as  
per the changed settings.  
3
Select the setting item and change the  
setting.  
When performing the settings with  
the convertible camera:  
Press the MENU or ITEM/AWC  
switch to move the flashing to the  
desired setting item, then press  
the YES/ABC or NO/BAR switch to  
change the setting.  
When performing the settings with  
the remote control unit (AW-RC600):  
Press the ITEM UP or ITEM DOWN  
switch to move the flashing to the  
desired setting item, then press the  
DATA YES/UP or DATA NO/DOWN  
switch to change the setting.  
- 1ꢀ (E) -  
Setting and changing of menu items  
Optional card settings submenu  
Safety zone (1 to 4, OFF)  
This selects the type of safety zone that  
is displayed in the viewfinder.  
If “OFF” is selected, a safety zone will  
not be displayed.  
<Note>  
The safety zone and the center marker  
reflect the electrical positions which may  
differ from the optical positions.  
Zebra indicator (ON, OFF)  
This sets the zebra pattern display  
which appears in the viewfinder.  
ON: Zebra patterns are displayed in  
the viewfinder.  
OFF: Zebra patterns are not displayed  
in the viewfinder.  
<Note>  
Even if “ON” is selected for this setting,  
the zebra patterns will not be displayed  
in the viewfinder if “CVBS” has been  
selected as the EVF output setting.  
The inner frame and the outer frame  
are approximately 90% and 95%,  
respectively, of the safety zone.  
Level (70% to 110%)  
EVF output (Y, CVBS)  
This sets the signals to be output to the  
viewfinder.  
The zebra patterns are displayed to use  
as a yardstick for the brightness level.  
Y:  
Brightness signals are output to  
the viewfinder.  
<Note>  
These settings are available when  
“ON” has been selected for the Zebra  
indicator setting.  
CVBS: Color signals are output to the  
viewfinder.  
<Note>  
The zebra pattern is not displayed in  
the viewfinder when “CVBS” has been  
selected.  
- 1ꢀ (E) -  
Appearance  
Unit: mm  
SDI card  
70  
- 14 (E) -  
Appearance  
Unit: mm  
Interface bracket  
50  
190  
141  
30  
- 15 (E) -  
Specifications  
Power requirements: DC 1ꢁ V (supplied from convertible camera)  
Power consumption: 15 W (When WV-VF65B, AW-VF80 is connected)  
indicates safety information.  
Ambient operating temperature: –10°C to +45°C  
Ambient operating humidity:  
ꢀ0% to 90% (without condensation)  
Dimensions (WHD):  
SDI card  
ꢁ1.5709ꢁ mm (excluding protrusions)  
Interface bracket  
19018ꢀ171 mm (excluding protrusions)  
Weight:  
SDI card  
Interface bracket  
0.10 kg  
1.06 kg  
Input/output connectors:  
SDI card  
SDI OUT 1, ꢁ connector  
EVF I/F connector  
Interface bracket  
EVF connector 1  
BNC, compliant with EBU Tech.ꢀꢁ67-E standard  
10-pin, round  
10-pin, round, composite signals/brightness, 1.0 V [P-P]  
EVF connector ꢁ  
6-pin, round, composite signals/brightness, 1.0 V [P-P]  
Inter-communications jack  
TALLY input connector  
Mꢀ  
BNC  
Switch/control functions:  
SDI card  
• EDH  
• Model selection  
• DATA CLIP  
ENABLE/DISABLE  
Eꢀ50/E860  
NORMAL/CLIP  
• NTSC/PAL switching NTSC/PAL  
EVF standby / VIDEO ON/OFF switch  
WV-VF65B, AW-VF80 ST.BY/ON  
Interface bracket  
Menu screens  
AW-VF64  
VIDEO ON/VIDEO OFF  
Inter-communications level control  
Zebra indicator (ON/OFF)  
Level (70% to 110%)  
Safety zone (1/ꢁ/ꢀ/4/5/OFF)  
EVF output (Y/CVBS)  
Weight and dimensions indicated above are approximate.  
Specifications are subject to change without notice.  
- 16 (E) -  

Planar Systems Car Video System LX0801PTI User Manual
Pioneer AVIC F700BT User Manual
Philips Food Processor HR7740 User Manual
Panasonic Camcorder DMC FH25 User Manual
Nikon 55 300 User Manual
Nikon 1 V1 User Manual
National Products BW3 User Manual
MTX Audio TA4252 User Manual
KitchenAid KSB580NK0 User Manual
JVC kd sc601 User Manual